Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Am Dent Assoc ; 149(1): 59-66, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29304911

RESUMEN

BACKGROUND AND OVERVIEW: Although calcium hydroxide (Ca[OH]2) paste associated with barium sulfate (BaSO4) is considered a safe agent, there is a lack of clinical research on its effects on periodontal and submucosal tissues. The aim of the authors was to report the effects of extrusion of Ultracal XS paste (Ultradent Products) in 2 cases. The authors also analyzed the paste constituents and compared them with the proportion reported by the manufacturer and the material extruded. CASE DESCRIPTION: The authors present 2 cases in which root canals were restored with Ultracal XS paste after cleaning and shaping, and there was unintentional overextension of the paste into periradicular tissues, with a hardened exogenous material observed associated with inflammatory signs and symptoms. A biopsy was performed, and the material was subjected to histopathologic analysis and characterization through scanning electron microscopy, energy dispersive x-ray spectroscopy, Fourier transform infrared spectroscopy, and x-ray diffraction. CONCLUSIONS: BaSO4 and calcium carbonate (CaCO3) were associated with a hardened material after Ultracal XS paste extrusion. The Ca(OH)2 percentage on the Ultracal XS paste was approximately 2 times greater than the proportion reported by the manufacturer. PRACTICAL IMPLICATIONS: Ca(OH)2 with BaSO4 paste application should be performed carefully, and its extrusion to periradicular and submucosal tissues should not occur. Its extrusion may result in the formation of a persistent exogenous material of hardened consistency associated with inflammatory signs and symptoms.


Asunto(s)
Hidróxido de Calcio , Materiales de Obturación del Conducto Radicular , Sulfato de Bario
2.
Microsc Res Tech ; 80(8): 870-877, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28401681

RESUMEN

Oxalate-based products are effective against dentine sensitivity and have been studied as an option to improve long-term adhesive bonding strength. Our aim was to evaluate the effect of potassium oxalate on the microtensile bond strength (µTBS) of the dentin/resin interface after 24 h, 1, and 6 years. Dentin on the occlusal surface of 16 human premolars was exposed and etched with 35% phosphoric acid. The teeth were divided into four groups. Two groups received 3% monohydrated potassium oxalate and the following adhesive systems and composites: Adper Scotchbond Multipurpose + FiltekZ350 (3M/ESPE) and Prime & Bond NT + Esthet-X (Dentsply). Two control groups did not receive potassium oxalate. Teeth were cut into sticks and kept in distilled water at 37°C for 24 h, 1, and 6 years. The sticks underwent µTBS testing after storage. ANOVA, Tukey's post hoc test, and paired t test were used to compare storage times (α = 0.05). The fracture mode of the specimens was classified under a stereomicroscope (40×). Morphology of the hybrid layer and the fracture pattern were observed with scanning electronic microscopy (SEM). Mean µTBS was high at 24 h and decreased after 1 and 6 years. After 6 years, the mean µTBS values were similar with no statistically significant difference between the groups (p = .121). SEM images showed proper dentin hybridization. Dentin pretreatment with potassium oxalate did not affect hybrid layer formation, but bond strength decreased over time after 24 h. Therefore, the clinical use of potassium oxalate to increase dentin bond durability is not indicated.


Asunto(s)
Recubrimientos Dentinarios/farmacología , Dentina/efectos de los fármacos , Ácido Oxálico/farmacología , Recubrimiento Dental Adhesivo , Análisis del Estrés Dental , Estudios de Seguimiento , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...